Introduction
CDS Hooks is a technology from SMART on FHIR that allows third-party CDS systems to register with an EHR using a "hook" pattern. The third-party CDS system is able to provide the EHR with information in the form of "cards" that the EHR may use to show the end-user or otherwise interweave into the workflow. The HSPC Bilirubin system is able to use CDS Hooks to alert the EHR of babies that are at risk of Kernicterus.
Prerequisites
- Patient and observation data must be loaded into the EHR
- See datapack dstu2/usecases/cds-hooks.fhir-bundle.xml
- Birthdays must be for one day prior to the current date
- Observation effective date must be the same as the current date
Links
Example Using the HSPC Bilirubin System
SMART on FHIR Test Harness
STEP 1
Launch the SMART on FHIR Test Harness at http://hooks.fhir.me/
STEP 2
Enable the Bilirubin Patient View hook (hint: search for "bilirubin", select Configure Hooks again to close)
STEP 3
Select Patient View. This represents an EHR patient view screen "action"
STEP 4
Observe the default patient (not a baby) sees no Bilirubin Card
STEP 5
Select Change Patient and enter value of "ID-BabyWithoutBilirubinObservation"
STEP 6
Observe a Bilirubin card is returned to the EHR stating that the baby has no bilirubin observations
STEP 7
Select Change Patient and enter the value of "ID-BabyWithBilirubinObservation"
STEP 8
Observe a Bilirubin card is returned to the EHR stating that the baby has a bilirubin level that exceeds thresholds.